Nortel DMS-100 Series Maintenance Manual page 134

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-20 RLCM-EDC alarm clearing procedures
PM LCM
major
(continued)
Clearing an PM LCM major alarm
At the MAP terminal
1
2
3
4
5
6
Link 0: LTC 0
Link 1: LTC 0
297-8381-550 Standard 02.02 April 1999
To silence an audible alarm, type
>MAPCI;MTC;SIL
and press the Enter key.
To access the PM level of the MAP display, type
>PM
and press the Enter key.
To identify the RLCM-EDC that has faults, type
>DISP STATE ISTB LCM
and press the Enter key.
To post the RLCM-EDC with the alarm condition, type
>POST LCM site cabinet lcm
and press the Enter key.
where
site
is the site name of the RLCM-EDC (alphanumeric)
cabinet
is the cabinet number of the RLCC-EDC
lcm
is the number of the LCM
To determine the fault indicators, type
>QUERYPM FLT
and press the Enter key.
If fault indicated
is CBsy
is SysB
is ManB
To identify the C-side links to the host Line Trunk Controller PLUS (LTC+), type
>TRNSL C
and press the Enter key.
Example of a MAP response:
Do
step 6
step 13
step 14
2; Cap MS; Status: OK
6; Cap MS; Status: SysB
;MsgCond: OPN
;MsgCond: CLS