6-6
6-6
RLCM-EDC card replacement procedures
NT0X91
in FSP
Application
Use this procedure to replace the following card in the shelves or frames
identified in the following table.
PEC
NT0X91
If you cannot identify the PEC, suffix, and shelf or frame for the card you
want to replace, refer to the Index for a list of cards, shelves, and frames
documented in this maintenance manual.
Common procedures
None
Action
The following flowchart is only a summary of the procedure. To replace the
card, use the instructions in the step-action procedure that follows the
flowchart.
297-8381-550 Standard 02.02 April 1999
6-6
Suffixes
Cardname
AA, AE
FSP drive and alarm
circuit pack
Shelf/frame name
FSP/RLCC