Nortel DMS-100 Series Maintenance Manual page 259

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT6X21 card in an LCM
At your current location
1
Obtain a replacement card. Make sure the replacement card has the same
product equipment code (PEC), and PEC suffix, as the removed card.
At the MAP terminal
2
To access the LTP level of the MAP terminal and post the line, type
>MAPCI;MTC;LNS;LTP;POST L site lcm lsg ckt
and press the Enter key.
where
site
is the name of the site and the location of the RLCM-EDC
lcm
is the number of the RLCM-EDC LCM with the defective card
lsg
is the number of the line subgroup with the defective card
ckt
is the number of the circuit that associates with the defective card
Example of a MAP response:
LCC PTY RNG .....LEN.......... DN
PPHON
REM1 00 0 03 03
3
Check the status of the posted line.
If the line status is
manual busy (ManB)
not ManB
4
To busy the line, type
>BSY
and press the Enter key.
At the RLCC cabinet
5
Go to the procedure "Replacing an NT6X21 card". When the procedure is
complete, return to this point.
RLCM-EDC card replacement procedures 6-71
STA F S LTA TE RESULT
7213355 MB
Do
step 5
step 4
DMS-100 Family Maintenance Manual ABSK007
NT6X21
in LCM
(continued)