Nortel DMS-100 Series Maintenance Manual page 128

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-14 RLCM-EDC alarm clearing procedures
PM LCM
PM LCM
critical
critical
(continued)
(end)
31
Existing loads: Unit 0: Act:REDC07AA *FLT*
New loads after a successful RTS will be:
Do you wish to continue?
Please confirm ("YES", "Y", "NO", or "N"):
>Y
32
297-8381-550 Standard 02.02 April 1999
To attempt to RTS the LCM unit and switch load to standby bank, type
>RTS UNIT lcm_unit SWLD
and press the Enter key.
where
lcm_unit
is the LCM unit of the RLCM-EDC to RTS (0 or 1)
Example of a MAP response:
Unit 0: Act:REDC07AA
If RTS
passes
fails
The procedure is complete.
Go to the correct alarm clearing procedure if additional alarms appear.
Stby:REDC07AA
Stby:REDC07AA *FLT*
Do
step 32
step 25