Nortel DMS-100 Series Maintenance Manual page 109

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

RLCM-EDC recovery procedure
16
Check if links to the RLCM-EDC are stable. To find and record the link
numbers for this RLCM-EDC, type
>TRNSL C
and press the Enter key.
Example of a MAP response:
Link
0:
Link
1:
Link
2:
Link
3:
Note: Record the link information for use later in this procedure.
17
To access the CARRIER level of the MAP, type
>TRKS;CARRIER
and press the Enter key.
Host LTC P-side link number
LTC 1
0;Cap MS;Status:OK ;MsgCon:OPN
LTC 1
2;Cap MS;Status:OK ;MsgCon:OPN
LTC 1
3;Cap
LTC 1
4;Cap
DMS-100 Family Maintenance Manual ABSK007
RLCM-EDC recovery procedures 4-9
S;Status:OK
S;Status:OK
(continued)