Nortel DMS-100 Series Maintenance Manual page 270

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-82 RLCM-EDC card replacement procedures
NT6X50
in HIE
(continued)
9
10
11
12
At the RLCE frame
13
297-8381-550 Standard 02.02 April 1999
To post the LCM, type
>POST LCM site cabinet lcm
and press the Enter key.
where
site
is the name of the RLCM-EDC site (alphanumeric)
cabinet
is the number of the RLCC cabinet
lcm
is the number of the LCM
To busy LCM unit 0 for card in slot 19 or LCM unit 1 for card in slot 20, type
>BSY UNIT lcm_unit_no
and press the Enter key.
where
lcm_unit_no
is the RLCM-EDC unit (0 or 1) to busy
To post the C-side PM, posted before in step 5, where the RLCM-EDC
connects, type
>POST LTC ltc_no
and press the Enter key.
where
ltc_no
is the number of the host LTC+ (0 to 255)
To busy both links associated with the defective card, use the information
collected in steps 6 and 7. Type
>BSY LINK link_no
and press the Enter key.
where
link_no
is one of two links associated with the defective card
Note: Repeat this step for the other link associated with the defective card.
WARNING
Possible interruption of calls in progress.
Operating company personnel must wait at least 15 min
before removal of the NT6X50 DS-1 interface card.
Personnel must wait this time to allow callers to complete
calls in progress.