Summary of replacing an NT6X51 card in LCM
At PM level of MAP,
post the LCM
Busy the LCM unit
with the defective
card
Replace the card
with one having
identical PEC
Query the OOS
LCM unit for valid
loadfiles
Is loadfile
valid?
N
Load the LCM unit
Return the busied
LCM unit to service
Y
Return LCM unit to
service
RTS pass?
N
RLCM-EDC card replacement procedures 6-87
This flowchart summarizes the
procedure.
Use the instructions that follow
this flowchart to perform the
procedure.
RTS pass?
N
Y
End of procedure
Contact
maintenance
support group
DMS-100 Family Maintenance Manual ABSK007
NT6X51
in LCM
(continued)
Y
End of procedure