5-62 RLCM-EDC alarm clearing procedures
PM LCM
minor
(continued)
At the MAP terminal
6
Link 0: LTC 0
Link 1: LTC 0
7
8
Link 2: LCM REM1 00 0
Link 6: LCM REM1 00 0
9
297-8381-550 Standard 02.02 April 1999
To identify C-side links to the host Line Trunk Controller PLUS (LTC+), type
>TRNSL C
and press the Enter key.
Example of a MAP response:
To post the host LTC+, type
>POST LTC ltc_no
and press the Enter key.
where
ltc_no
is the number of the host LTC+ identified in step 6
To identify the P-side links that have faults, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
Note: Record information for the links that have a status other than OK.
To choose and busy the link that has faults, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link identified in step 8
2; Cap MS; Status: OK
6; Cap MS; Status: SysB
2;Cap MS;Status: OK
1;Cap MS;Status: SysB,;MsgCond: CLS
;MsgCond: OPN
;MsgCond: CLS
;MsgCond: OPN