Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-16 RLCM-EDC card replacement procedures
NT0X91
NT0X91
in FSP
in FSP
(continued)
(end)
49
50
51
52
53
54
297-8381-550 Standard 02.02 April 1999
Post the RMM that is controlled by the alarm and control card you have just
replaced by typing
>POST RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM to be posted, as recorded in step 5
Load the RMM by typing
>LOADPM
and pressing the Enter key.
If Loadpm
passed
failed
Return the RMM to service by typing
>RTS
and pressing the Enter key.
If the rmm
RTS passed
RTS failed
Return to the maintenance procedure that sent you to this procedure and
continue as directed.
For further assistance, contact the personnel responsible for the next level of
support.
You have completed this procedure.
Do
step 51
step 53
Do
step 44
step 53