Nortel DMS-100 Series Maintenance Manual page 303

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

How to replace an NT6X74 card in RMM
At your current location
1
Obtain a replacement card. Make sure that the replacement card has the same
product equipment code (PEC) and PEC suffix as the card to remove.
2
If another maintenance procedure directs you to this procedure, go to step 8. If
another maintenance procedure does not direct you to this procedure, proceed
to step 3.
At the MAP display
3
To access the trunk test position (TTP) level of the MAP terminal and post the
remote maintenance module (RMM) that contains the card to replace, type
>MAPCI;MTC;TRKS;TTP;POST P RMM rmm_no
and press the Enter key.
where
rmm_no
is the number of the RMM shelf in which you replace the card
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
20
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
MF RMM 0 0
4
Check the status of the RMM trunk circuits.
If RMM status
is MB, PMB, RMB
is other than listed here
5
To busy the trunks that associate with the card you must replace, type
>BSY ALL
and press the Enter key.
RLCM-EDC card replacement procedures 6-115
OTDA00
BUSY Q
COM LANG
OTWAON23DA00 2001
Do
step 6
step 5
DMS-100 Family Maintenance Manual ABSK007
NT6X74
in RMM
(continued)
DIG
STA S R DOT TE R
LO
P_IDL