Powering Down The Rlcm-Edc - Nortel DMS-100 Series Maintenance Manual

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

10-6 Advanced troubleshooting procedures

Powering down the RLCM-EDC

Power down the RLCM-EDC from the MAP terminal with the use of the
following steps:
1 Post the LCM part of the RLCM-EDC.
2 Identify the unit to power down.
3 To busy the RLCM-EDC unit, type
4 To remove the power from the busied RLCM-EDC unit, set CB on the
5 You powered down the RLCM-EDC unit.
6 Repeat this procedure for the mate unit.
297-8381-550 Standard 02.02 April 1999
CAUTION
Loss of service
Reserve this procedure for extreme conditions, like an
impending natural disaster. This procedure results in a
loss of subscriber service.
>BSY UNIT unit_no
and press the Enter key.
where
unit_no is the number of the unit to power down
FSP to OFF.
FSP circuit breaker assignments
Shelf
CB
type
CB2
LCA
CB3
HIE
CB4
RMM
CB7
LCA
CB8
HIE
Shelf
Slot
pos.
pos.
05
01
33
26
47
17/20
19
01
33
22
PEC code
Equipment
NT6X53AA
LCM unit 0
NT2X70AF
NT6X50/73
NT2X09AA/
RMM
NT2X06AB
NT6X53AA
LCM unit 1
Nt2X70AF
NT6X50/73