Nortel DMS-100 Series Maintenance Manual page 300

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-112 RLCM-EDC card replacement procedures
NT6X73
NT6X73
in HIE
in HIE
(continued)
(end)
At the HIE shelf
7
8
At the MAP terminal
9
10
11
12
13
297-8381-550 Standard 02.02 April 1999
To busy the LCM unit associated with the damaged NT6X73, type:
>BSY UNIT unit_no
and press the Enter key.
where
unit_no
is the LCM unit number zero or one associated with the defective
card.
To replace the NT6X73 card, use the procedure the Replacing a card
procedure.
If another maintenance procedure directed you to this procedure, return to the
alarm clearing procedure that directed you here. If another maintenance
procedure did not direct you to this procedure, continue with step 9.
To return the busy LCM unit to service, type:
>RTS UNIT unit_no
and press the Enter key.
where
unit_no
is the LCM unit zero or one busied in step 6
If RTS
fails
passes
Send the defective cards for repair according to local procedure.
Record the following items in office records:
date of card replacement
serial number of the card
problems that prompted replacement of the card.
Proceed to step 13.
For additional help, contact the next level of support.
This procedure is complete.
Do
step 12
step 10