Nortel DMS-100 Series Maintenance Manual page 168

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-54 RLCM-EDC alarm clearing procedures
PM RMM
major
(continued)
26
27
28
297-8381-550 Standard 02.02 April 1999
To post the LCM identified in step 25, type
>POST LCM site cabinet lcm
and press the Enter key.
where
site
is the site name of the RLCM-EDC (alphanumeric)
cabinet
is the cabinet number of the RLCC-EDC
lcm
is the number of the LCM
CAUTION
If you do not allow the time required for the system to
clear the alarm, a false alarm indication can occur.
Allow 3 to 5 min for the system to clear the alarm
before you proceed to the next step.
To identify the P-side links that have faults, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
LINK
0: RMM 0 0;CAP MS;STATUS:SysB,;MSGCOND: CLS
LINK
1: RMM 0 1;CAP MS;STATUS:SysB,;MSGCOND: CLS
To busy the link that has faults, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link identified in step 27