Nortel DMS-100 Series Maintenance Manual page 32

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-20 Maintenance overview
RTS command The RTS command retains all existing functionality. The
new options SMEM and SWLD are added to the RTS command to return to
service only the smaller memory (64K/256K) LCMs and activate new loads
in 4M LCMs. The SMEM option is applicable only when option ALL is
used. The following response is observed when the RTS command is used
with options ALL and SMEM.
>RTS UNIT 0 ALL SMEM
Example of MAP response
This operation will be performed on 2 LCMs.
Please confirm ("YES","Y","NO","N"):.
>Y
LCM HOST 02 0 Unit 0 Calls On Unit May Be Affected
Please confirm ("YES", "Y", "NO", or "N"):
>Y
LCM REM1 01 0 Unit 0 Request not submitted:Not an SMEM LCM
LCM HOST 02 0 Unit 0 Bsy passed
Summary:
1 Passed.
1 not submitted
The RTS command, without any options, is used to RTS a unit or whole PM
using the load in the active bank. If the unit or PM fails to RTS the
operating company personnel can retry the RTS command with the SWLD
option.
>RTS UNIT 0
Example of MAP response
LCM REM1 01 0 Unit 0 Invalid Active load.
The SWLD option is added to the RTS command to activate new loads in
the STBY bank of the specified unit or whole PM. The SWLD option is
applicable only to RLCM-EDC nodes. The SWLD option is valid only
when the unit or LCM is in a ManB state.
>RTS UNIT 0 SWLD
Example of MAP response
LCM REM1 01 0 Unit 0 Invalid Standby load.
297-8381-550 Standard 02.02 April 1999
Use QueryPM to check loads.
Use QueryPM to check loads.