10-2 Advanced troubleshooting procedures
2 To BSY both LCM units, type
3 Reference the following table for circuit breaker (CB) and power
4 At the remote site, set the switch on the power converter (NT2X70AF)
5 While you hold in the reset button on the power converter in slot 26, flip
6 To translate the C-side links of the LCM to obtain the host LTC+ node
297-8381-550 Standard 02.02 April 1999
>BSY PM
and press the Enter key.
converter assignments.
FSP circuit breaker assignments
Shelf
CB
type
CB2
LCA
CB3
HIE
CB4
RMM
CB7
LCA
CB8
HIE
in slot positions 22 and 26 of the Host Interface Equipment shelf (HIE)
to the ON position.
the appropriate circuit breaker up. Do not hold this circuit breaker in the
up position. If power is applied to the HIE, the circuit breaker will stay
in the ON position. If a problem with the power is present, the circuit
breaker will trip back down to the OFF position.
Note: Repeat steps 4 and 5 for the NT2X70AF in slot 22.
Note: Repeat steps 4 and 5 for the other line concentrating module
(LCM) unit.
number, type
>TRNSL C
and press the Enter key.
Shelf
Slot
pos.
pos.
05
01
33
26
47
17/20
19
01
33
22
PEC code
Equipment
NT6X53AA
LCM unit 0
NT2X70AF
NT6X50/73
NT2X09AA/
RMM
NT2X06AB
NT6X53AA
LCM unit 1
Nt2X70AF
NT6X50/73