Nortel DMS-100 Series Maintenance Manual page 250

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-62 RLCM-EDC card replacement procedures
NT2X90
in RMM
(continued)
11
12
13
14
15
16
17
18
297-8381-550 Standard 02.02 April 1999
To return the tested circuit to service,
>RTS
and press the Enter key.
If the RTS
passed
failed
To place the not tested circuit in the control position, type:
>NEXT 1
and press the Enter key.
To test the circuit, type
>TST
If the TST
passed
failed
To return to service and clear the trunk test position,
>RTS;NEXT
and press the Enter key.
Send any cards that have faults for repair according to local procedure.
Record the items that follow in office records:
date you replace the card
serial number of the card
problems for the replacement of the card
Go to step 20.
Return to the Alarm clearing procedures that sent you to this card replacement
procedure. Go to the point where the system produced the damaged card list
and identify the next damaged card on the list. Proceed to the correct
replacement procedure in this manual for the card.