Nortel DMS-100 Series Maintenance Manual page 31

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

The following MAP display response is observed when the BSY command
is executed with the ALL option but not the SMEM suboption.
>BSY UNIT 0 ALL
Example of MAP response
This will cause ALL LCMs in the posted set to be busied.
The SMEM option of the BSY command should be
used if loading the 4M LCMs in-service is desired.
This operation will be performed on 2 LCMs.
Please confirm ("YES","Y","NO","N"):.
>Y
LCM REM1 01 0 Unit 0 Bsy passed
LCM HOST 02 0 Unit 0 Bsy passed
Summary:
2 Passed.
Options of the BSY command and their descriptions are listed in the
following table, "Options of the BSY command," as they relate to the
RLCM-EDC product.
Options of the BSY command
Command
Parameter
BSY
ALL
BSY
SMEM
Description
Busy all PMs or units currently posted at the PM level of
the MAP display in the posted set.
This option is intended for use with the ALL option when
preparing to parallel load a set of LCMs
The command busies the 64K and 256K LCMs but
leaves the 4M LCMs InSv.
DMS-100 Family Maintenance Manual ABSK007
Maintenance overview 1-19
(64K, 256K).