4-6 RLCM-EDC recovery procedures
RLCM-EDC recovery procedure
7
8
9
297-8381-550 Standard 02.02 April 1999
To display the peripheral side (P-side) links, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
Link 2:LCM REM1 00 0
Link 6:LCM REM1 00 0 1;Cap MS;Status:SysB;MsgCond:CLS
Note: Record information for the links that have a status other than OK.
To busy the defective link, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a defective P-side link identified in step 7
Note: Repeat this step for each defective link.
To test the busy link, type
>TST LINK link_no
and press the Enter key.
where
link_no
is the number of a damaged P-side link busied in step 8
Note: Repeat this step for each busy link.
If test
passes
fails
(continued)
0;Cap MS;Status:SysB;MsgCond:CLS
Do
step 10
step 24