Nortel DMS-100 Series Maintenance Manual page 170

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-56 RLCM-EDC alarm clearing procedures
PM RMM
PM RMM
major
major
(continued)
(end)
32
33
34
35
36
297-8381-550 Standard 02.02 April 1999
To return the ManB RMM to service, type
>RTS
and press the Enter key.
If RTS
passes
fails
The card list identifies the cards with possible faults. Replace the cards one
card at a time in the order listed top to bottom.
If you
replaced all the cards on the list
did not replace all the cards on
the list
Refer to the card replacement procedure in the Card Replacement Procedures
for the card that follows on the card list. When you complete the card
replacement procedures, go to step 7 of this procedure.
For additional help, contact the next level of support.
The procedure is complete. If other alarms appear, refer to the appropriate
alarm clearing procedures for the indicated alarms.
Do
step 36
step 35
Do
step 35
step 34