Replacing an NT6X52 card in an LCM
At your current location
1
Obtain a replacement card. Make sure that the replacement card has the same
product equipment code (PEC) and suffix as the card to remove.
2
If another maintenance procedure, proceed to step 5. If this event did not
occur, proceed to step 3.
At the MAP display
3
To access the peripheral module (PM) level and post the line concentrating
module (LCM), type
>MAPCI;MTC;PM;POST LCM site cabinet lcm
and press the Enter key.
where
site
is the site name of the RLCM_EDC (alphanumeric)
cabinet
is the number of the RLCC cabinet
lcm
is the number of the LCM
4
To busy the LCM unit that contains the defective card, type
>BSY UNIT unit_no
and press the Enter key.
where
unit_no
is the LCM unit (0 or 1) to busy
At the RLCC cabinet
5
Use the procedure "Replacing a card" to replace the NT6X52 card.
6
If another maintenance procedure directed you to this procedure, return now to
the procedure that directed you here. Continue as directed. If this event did
not occur, proceed to step 8.
RLCM-EDC card replacement procedures 6-93