Nortel DMS-100 Series Maintenance Manual page 185

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Clearing an PM RMM minor alarm
At the MAP terminal
1
To silence the alarm, type
>MAPCI;MTC;PM;SIL
and press the Enter key.
2
To identify the defective RMM, type
>DISP STATE ISTB RMM
and press the Enter key.
Example of a MAP response
ISTb
RMM: 2
3
To post the in-service trouble (ISTB) RMM from step 2, type
>POST RMM rmm_no
and press the Enter key.
where
rmm_no
is the number of the RMM that has defects
4
To perform an in-service test on the RMM that has defects, type
>TST
and press the Enter key.
If test
passes
fails because of C-side links not
available
fails and the system produces a
card list
fails and the system does not
produce a card list
RLCM-EDC alarm clearing procedures 5-71
Do
step 16
step 5
step 13
step 15
DMS-100 Family Maintenance Manual ABSK007
PM RMM
minor
(continued)