Nortel DMS-100 Series Maintenance Manual page 120

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-6 RLCM-EDC alarm clearing procedures
PM LCM
critical
(continued)
7
8
9
297-8381-550 Standard 02.02 April 1999
To display the peripheral side (P-side) links of the LTC+, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
Link 2: LCM REM1 00 0
Link 6: LCM REM1 00 0
Note: Record information for the links that have a state other than OK.
To busy the link that has faults, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link identified in step 7
To test the busied link, type
>TST LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link made busy in step 8
If test
passes
fails
2; Cap MS; Status: SysB ;MsgCond: CLS
1; Cap MS; Status: SysB ;MsgCond: CLS
Do
step 10
step 17

Advertisement

Table of Contents
loading

Table of Contents