Nortel DMS-100 Series Maintenance Manual page 254

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-66 RLCM-EDC card replacement procedures
NT3X09
in RMM
(continued)
Replacing an NT3X09 card in an RMM
At your current location
1
At the MAP terminal
2
3
4
5
297-8381-550 Standard 02.02 April 1999
Obtain a replacement card. Make sure that the replacement card has the same
product equipment code (PEC), and PEC suffix, as the removed card.
To access the TTP level of the MAP terminal and post the RMM, type
>MAPCI;MTC;TRKS;TTP;POST P RMM rmm_no ckt_no
and press the Enter key.
where
rmm_no
is the number of the RMM shelf, the location of the card to remove
ckt_no
is the number of the first circuit and the location of the NT3X09 card
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
20
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
MISC RMM 0 0
To verify the location of the correct card slot, type
>CKTLOC
and press the Enter key.
Check the status of the RMM.
If RMM status is
MB, PMB, RMB
other than listed here
To busy the trunks that associate with the card, type
>BSY ;NEXT
and press the Enter key.
Note: Repeat this step for all circuits that associate with the defective NT3X09
card you must replace.
1118
BUSY Q
COM LANG
MTADRIVER 20
DIG
STA S R DOT TE R
LO
Do
step 6
step 5