Nortel DMS-100 Series Maintenance Manual page 206

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-18 RLCM-EDC card replacement procedures
NT2X06
in RMM
(continued)
Summary of replacing an NT2X06 card in RMM
At TRKS;TTP level,
post the RMM
trunks
Are the RMM
trunks busy?
N
Busy the trunks
associated with the
RMM
At PM level, post
and busy the RMM
297-8381-550 Standard 02.02 April 1999
Y
Power down the
RMM shelf
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
Replace card with
one having identical
PEC
Power up the RMM
shelf
Reload the RMM
RTS the RMM
At TRKS;TTP level,
post the RMM and
RTS trunks
End of procedure