Nortel DMS-100 Series Maintenance Manual page 214

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-26 RLCM-EDC card replacement procedures
NT2X09
in RMM
(continued)
6
7
At the RMM shelf
8
9
10
297-8381-550 Standard 02.02 April 1999
Access the PM level of the MAP display and post the RMM by typing
>PM;POST RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf in which the card is to be replaced
Example of a MAP display:
SysB
PM
0
RMM
1
RMM
0
SysB
Busy the RMM by typing
>BSY
and pressing the Enter key.
WARNING
Static electricity damage
Wear a wrist strap connected to the wrist strap
grounding point of a frame supervisory panel (FSP)
while handling circuit cards. This protects the cards
against damage caused by static electricity.
Power down the RMM by setting the ON/OFF switch on the power converter
faceplates of both the NT2X09 and NT2X06 to the OFF position. Both the
converter FAIL LED and FRAME FAIL lamp at the FSP will go to ON. An
audible alarm may sound. If an alarm does sound, silence it at the MAP
terminal by typing
>SIL
and pressing the Enter key.
At the FSP, set the circuit breaker CB4 to the OFF position
Replace the NT2X09 card using the procedure "Replacing a card". When you
have completed the procedure, return to this point.
ManB
Offl
2
2
0
0
CBsy
ISTb
0
7
0
0
InSv
21
6