Nortel DMS-100 Series Maintenance Manual page 162

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-48 RLCM-EDC alarm clearing procedures
PM RMM
major
(continued)
Summary of clearing a PM RMM major alarm
At PM level of
MAP, display
SysB RMMs
Post SysB
RMM
Busy RMM
Test RMM
4
Test passed?
N
Load failure?
N
C-side links
unavailable?
N
Card list
received
297-8381-550 Standard 02.02 April 1999
7
Return RMM
Y
to service
Y
1
Y
2
Replace card
This flowchart summarizes the
procedure.
Use the instructions that follow
this flowchart to perform the
procedure.
Y
Return to
service
passed?
N
Contact
maintenance
support group
1
End of
procedure