Nortel DMS-100 Series Maintenance Manual page 61

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

The FSP has circuit breakers (CB) to distribute –48V power to shelves in the
RLCC cabinet. Refer to the following figure, "FSP shelf layout," and table
"FSP circuit breaker assignments," for CB power distribution, assignments,
shelf type and slot position, PEC code and equipment supported.
FSP shelf layout
01
ABS
01
–48V fan
06
RG-0 05 33–26 47
CB1
Not to scale
FSP circuit breaker assignments
CB
Shelf type
CB1
HIE
CB2
LCA
CB3
HIE
CB4
RMM
CB5
TRK – A
CB6
HIE
CB7
LCA
CB8
HIE
CB9
TRK – B
Frame fail
08
Fan fail
Fan alm override
–48ABS bat ret
RG–1
TK–A
33–22 TK–B
19
CB9
Shelf pos.
33
05
33
47
33
19
33
01 +5V 05 06
+15V 10 11 –48V 15 RA R8
CAUTION
Slot pos.
PEC code
01
01
NT6X53AA
26
NT2X70AF
17
NT2X06AB
05
01
NT6X53AA
22
Nt2X70AF
DMS-100 Family Maintenance Manual ABSK007
Maintenance overview 1-49
Equipment
not used
LCM unit 0
Power converter
RMM
not used
not used
LCM unit 1
Power converter
not used
END
GND

Advertisement

Table of Contents
loading

Table of Contents