Nortel DMS-100 Series Maintenance Manual page 188

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-74 RLCM-EDC alarm clearing procedures
PM RMM
PM RMM
minor
minor
(continued)
(end)
13
14
15
16
297-8381-550 Standard 02.02 April 1999
The card list identifies the cards that can be defective. Replace the cards one
at a time according to the procedure.
If the cards on the list
were replaced
were not replaced
Go to the Card Replacement Procedures for the next card on the card list.
When you finish with the card replacement procedures, go to step 12.
For additional help, contact the next level of maintenance.
The procedure is complete. If other alarms appear at the MAP display, refer to
the correct alarm clearing procedures.
Do
step 15
step 14