Nortel DMS-100 Series Maintenance Manual page 212

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-24 RLCM-EDC card replacement procedures
NT2X09
in RMM
(continued)
Summary of replacing an NT2X09 card in RMM
At TTP level, post
the RMM
Is the RMM
status ManB?
N
Busy the trunks
associated with the
RMM
At PM level, post
and busy the RMM
297-8381-550 Standard 02.02 April 1999
Y
Power down the
RMM shelf
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
Replace card with
one having identical
PEC
Power up the RMM
shelf
Reload the RMM
At PM level, return
RMM to service
At TTP level, post
the RMM and return
trunks to service
End of procedure