Pm Lcm Major - Nortel DMS-100 Series Maintenance Manual

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Alarm display
CM
.
Indication
The alarm code LCM under the PM subsystem header indicates an LCM
alarm. The
LCM indicates the number of LCMs that have a major alarm.
Meaning
The LCM is in-service trouble (ISTb) because of one of the following
conditions:
Result
The SysB and CBsy LCMsdo not directly affect service, because one unit of
the LCM still provides service. There is no local backup. Failure of the
other LCM unit will interrupt service.
A CBsy condition can interrupt communication between the RLCM-EDC
and the host. An interruption of communication between the RLCM-EDC
and the host reduces the service that the RLCM-EDC provides to the local
area. Out of service line drawers affect call processing. If all line drawers
are in-service call processing is not affected.
Common procedures
There are no common procedures.
Action
This procedure contains a flowchart and a list of steps. Use the flowchart to
review the procedure. Follow the steps to perform the procedure.
MS
IOD
Net
.
.
under the LCM indicates a major alarm. The number
M
one unit is system busy and one unit is ISTb
one unit is system busy and one unit is in-service
one unit is C-side busy and one unit is ISTb
one unit is C-side busy and one unit is in-service
5-15
RLCM-EDC alarm clearing procedures
PM
CCS
.
nLCM
.
M
DMS-100 Family Maintenance Manual ABSK007
PM LCM
Lns
Trks
Ext
.
.
.
5-15
5-15
major
Appl
.
before
n