For point-of-operation guarding the light curtain(s) and any mechanical guards should be
installed so no one can stand between the light curtain and the danger zone. This may require
additional hard guarding, horizontal or angled positioning of the light curtain, or additional light
curtains (see figure 1-2).
Figure 1-2 Point-of-operation Guarding (use FF-SB12, 14 or 30 only)
IMPROPER POINT-OF-OPERATION PROTECTION
Do NOT use FF-SB15 Series light curtains in point-of-operation applications.
Failure to comply with these instructions will result in death or serious injury.
Figure 1-3 Perimeter Guarding (use FF-SB12, 14, 15, or 30)
IMPROPER PERIMETER PROTECTION ACTIVATION
• Design control circuit that requires a manual restart before further machine operation can
occur.
• Locate manual restart to allow operator a clear view of danger zone.
• Operator must NOT be able to reach manual restart from within danger zone.
• Design control circuit to prevent Programmable Logic Controller from overriding manual
restart.
Failure to comply with these instructions could result in death or serious injury.
12 Honeywell • MICRO SWITCH Sensing and Control
FF-SB Series Installation Manual
For application help: call 1-800-537-6945