FACTORY SETTINGS
The muting module is set in the conveyor mode on delivery.
Refer to chapter 2.4.1 Selection of the appropriate mode, to select the press mode.
The maximum timing tmax allowed between SM sensors is set to 1 seconde on
delivery. For machines different than presses, it can be modified to the following values
: 2 s, 4 s, or 8 s.
The setting of the timing tmax also sets the muting maximum duration ∆max. In the press
mode, the muting duration is set to 1 mn on delivery. For machines different than presses, it can
be modified to the following values : 2, 4 or 60 mn.
Refer to chapter 2.4.2 SM inputs, to select tmax and ∆max.
TIMING CONDITIONS
The 8 ms minimum time difference between the two SMs inputs guarantees the
detection of a permanent short circuits of one of the SMs inputs. Physically, the 2
sensors must be slightly apart.
The activation of both EMs sensors must occur before the ∆max muting timing has
passed otherwise the muting module need to be restarted before restarting the press (refer to
chapters 2.4.5. Manual restart of the module and 4.8.2. Restart input).
Figure 3.9 :Example of an incorrect installation
EM2
EM2
EM1
EM1
SM1
SM1
4
SM2
SM2
3
BDC
Muting interrupted
Protection
(SM1released)
(SM1&SM2 activated)
BDC (Bottom Dead Center)
TDC (Top dead Center)
Because of the overtravel, the release and second actuation of the sensor SM1
interrupts the muting sequence. The intrusion of an object inside the dangerous
area immediately stops the machine.
107004-15 EN FR26 ROW 0899 Printed in France
SM1
SM2
OSSDs
ESPE
EM1
EM2
Muting
lamp
OSDs
muting
module
point at which the tool is closest to the die
point at which the tool is furthest to the die
45
1
0
1
0
1
0
1
0
1
0
1
0
1
0