IMPROPER SYSTEM PERFORMANCE
Ensure independent stop circuit safety relays have mechanically linked contacts that prevent
contact overlapping in the event of a welded contact.
Failure to comply with these instructions could result in death or serious injury.
IMPROPER INSTALLATION OF CE VERSION FF-SB SERIES LIGHT CURTAIN
Use Figure 3-7 wiring diagram to ensure external relay monitoring by the CE version of the
FF-SB Series Light Curtain.
Failure to comply with these instructions could result in death or serious injury.
Two versions of FF-SB Series light curtains exist: an Original version and a CE version. The
CE version may be used instead of an Original. However, an Original version will not work
(red condition) with the circuit illustrated in Figure 3-7.
Figure 3-7 Wiring Diagram for CE Version FF-SB Series configuration (except FF-
SB12R02)
RECEIVER
FF-SB12, FF-SB14
FF-SB15, FF-SB30 A1
Jumper Link position
on the Receiver
Power Board (to be
set up before
operation)
*Two arc suppressors are provided with the light curtain.
52 Honeywell • MICRO SWITCH Sensing and Control
ARC SUPPRESSOR
220 ohm + 0.22uF
R1
SUPPLY VOLTAGE
A2
R2
B1
B2
SUPPLY VOLTAGE
Additional output
C1
channel, may be
used to annunciate
C2
to PLC
C4
B3
A3
Signal Beam
Status
C5
B4
Not
connected
B5
C3
Cycle Start
C5
EARTH
GROUND
(Emitter and Receiver
must be grounded
for proper operation)
FF-SB Series Installation Manual
EMITTER AND
*
RECEIVER
NEUTRAL
SCREW ON
POWER
R1
R1
R2
INTERNAL FUSE
0.5 AMP
A4
SUPPLY VOLTAGE
A5
NEUTRAL
EARTH
GROUND
(Emitter and Receiver
must be grounded
for proper operation)
MACHINE CONTROL
R2
For application help: call 1-800-537-6945