The contact delivered by the test output can be either Normally Closed or Normally Open
according to the protective equipment (refer to the protective equipment installation
manual). This setting is done with the switch ST2 located inside the module. The removal of
the upper terminal strip eases access to the switch ST2 (ST2 is located below the 2 sets of
switches ST3 and ST1) :
SETTING ON DELIVERY
On delivery, the muting module provides a normally closed contact between terminals 28
and 29. Most of Honeywell protective equipment need a normally closed contact on their
test input with the exception of the FF-SCAN, FF-LS and FF-SPS4 modular light curtains
which needs a normally open contact.
muting module FF-SRM
switch ST2
TEST output
ON
NO contact
OFF *
NC contact*
(*) : position of the switch on delivery
Figure 4.8 : Selection of the test contact
Positon of the switch when the test contact is
Normally Closed :
107004-15 EN FR26 ROW 0899 Printed in France
the ESPE is in
test mode when :
contact is closed
contact is open *
ST2
27
26
25
24
23
22
21
2
+
-
+
-
RESTART
OSD 1
SM 1
EM 1
ST3
FF - SRM
RESET
ATUS
SM 2
EM 2
RESTART
OSD 2
STATUS
+
-
+
-
+
6
7
8
9
10
11
12
1
ST1
ST2
ST2
OFF
ON
55