Safety Distance Example One (Point-Of-Operation Guarding) - Honeywell SYA14 Series Manual

Safety light curtains
Table of Contents

Advertisement

Installation

Safety Distance Example One (Point-of-operation Guarding)

Point-of-operation is defined as that area where a machine performs work (such as cutting,
shaping, boring, or forming) on a material.
IMPROPER POINT-OF-OPERATION PROTECTION
Install the FF-SM Series safety mats and mechanical guards so that NO person can stand
between the safety mat and the danger zone without being detected.
Failure to comply with these instructions will result in death or serious injury.
Country:
USA
Application:
Mechanical or hydraulic power press
Protection:
Point-of-operation guarding
Formula:
D
V = 63 in./sec.
t
= 0.025 sec (FF-SM)
1
t
= 0.200 sec (machine stop time; including the response time of all interconnected
2
components, such as relays, solenoids, brakes, etc.)
C = 66 in. (ANSI B11.1 and ANSI B11.2) [FF-SM]
D
= 63 (0.025 + 0.200) + 66 in. = 80.18 in.
S
14 Honeywell • PK 107007-01 EN FR26 GLO 0298 Printed in France
>V(t
+t
)+C
S
1
2
FF-SM Series Installation Manual
For application help: see Warranty Information