Honeywell SYA14 Series Manual page 715

Safety light curtains
Table of Contents

Advertisement

FF-SRS5939 Series
SPECIFICATIONS
Supply Voltage
Nominal voltage (A1/A2)
Power consumption
Fuse protection
Restart Functions
Restart push-button input
(S33/S34)
Restart mode input
(X1/X3)
Restart time
FSD Monitoring Loop
FSD contacts input
(Y1/Y2)
FSD monitoring input
(X1/X2)
ESPE inputs
Input current
Input voltage
Protection
Outputs
Contacts available
Response time
Start time at power up
Current Range
Voltage Range
Switching Capability per
AC15 (EN 60947-5-1)
Typical electrical life
expectancy on 100 %
resistive load (see fig.1,
note 3)
Typical Power Factor
/AC voltage
(see fig. 2, note 2)
Operating frequency
External fuse rating
Mechanical life
Environmental Specifications
Temperature range
Sealing
Housing material
Vibration resistance
Connection
Mounting
Weight
NOTE 1: Install arc suppression device across loads to avoid module contact arcing and
ensure specified relay life expectancy.
NOTE 2 Total operations = operations at power factor 1 multiplied by the limitation factor.
If the power factor is 0.5 at 230 Vac, 3A (500,000 operations), the limitation factor is 0.70.
and the number of operations is 500,000 x 0.70 = 350,000.
2
24 Vdc (-15%, +15%)
3.5 W
315 mA, time delayed (see fig. 7 for location)
for the connection of a NO contact, 0.1s to 1.5s closing
time, permanent short-circuit detection, 20 Vdc min.
voltage (without pressing the push-button), 10 mA/24Vdc
min. current, 470Ω max. cable resistance
for setting the manual or automatic restart mode, voltage
presence
100 ms after the ESPE inputs are energized (automatic
restart mode) or push-button release (manual restart
mode)
for the connection in series of the FSDs NC contacts
(FSDs reaction time : 250 ms), permanent short-circuit
detection, 20 Vdc min. voltage, 30 mA/24Vdc min.
current , 150Ω max. cable resistance
for setting the FSD monitoring loop, voltage presence
30 mA / 24Vdc (when relays are energized); 5mA / 24
Vdc (when relays are deenergized)
19 to 27.6 Vdc
reversed polarity, over-voltages up to 32 Vdc
2 NO, 1 NC (2 safety relays with guided contacts)
15 ms max. (see timing diagrams)
100 ms (automatic restart mode)
1 mA min., 6A max. (see caution)
0.1 Vac/dc min., 250 Vac/dc max.
NO contact: 3 A / 230 Vac
NC contact: 2A / 230 Vac
1A
2,000,000 AC
3A
500,000 AC
5A
300,000 AC
6A
200,000 AC
Limitation Factor : 0.45 (cos ϕ = 0.3), 0.70 (cos ϕ = 0.5),
0.85 (cos ϕ = 0.7), 1.00 (cos ϕ = 1.0)
1200 switching cycles/h (max.)
6 A max. time delayed
10 million switching operations
Operation : 0 to 55°C (32 to 131°F) / Storage : -20 to
70°C (-4 to 170°F), at 90% humidity max.
Housing IP 40; Terminals IP 20 (need to be installed in
an IP54 enclosure)
Thermoplastic
Amplitude 0.35 mm (0.014 in.); Frequency 10 to 55 Hz
Removable terminal strips, one ∅2.5 mm
two ∅1.5 mm
2
(16 AWG) stranded wires per terminal
Quick install rail mounting EN 50022-35, 35 x 15 mm
(1.38 x 0.59 in.) size
280 g (0.61 lb.)
PK107033-EN
FIG. 1.
100% RESISTIVE LOAD / AC
VOLTAGE (typical) (note 1)
power factor = 1 (cos ϕ)
FIG. 2. LIMITATION FACTOR FOR
INDUCTIVE
VOLTAGE (note 2)
power factor < 1 (cos ϕ)
400,000 DC
300,000 DC
200,000 DC
150,000 DC
CAUTION
CONTACT DAMAGE
To ensure the 1 mA capability
during the lifetime of the contact,
NEVER exceed 300 mA and 60 V.
FIG. 3. TOTAL CURRENT LIMIT
Σ
Ã
ÃDÃ6
6
5
4
3
2
2
(14 AWG) or
1
32
107033-12 EN FR26 GLO 0499 Printed in Germany
CONTACT LIFE FOR
LOADS
0
10
20
30
40
50
50
68
86
104
122
/
AC
60
T(°C)
140
T(°F)