SPECIFICATIONS
Input
Nominal voltage
Nominal power consumption
Nominal frequency
Start time
Nominal voltage at S11
Input current between
S11/S12 and S21/S22
Minimum voltage at S12/A2
Cable resistance between
S11/S12 and S21/S22
Output
Contact complement
Response time
Contact type
Current Range (min. to max.)
Voltage Range (min. to
Switching Capability per
AC15 (EN 60947-5-1)
Typical Electrical Life
Expectancy
Typical Power Factor (cos ϕ)
Operating frequency
Output contact fuse rating
Mechanical life
General
Temperature range
Sealing
Housing material
Vibration resistance
Wire/conductor connection
Wire/conductor attachment
Mounting
Weight
NOTE 1: Install arc suppressors across load to avoid module contact
arcing and ensure specified contact life expectancy.
NOTE 2: Total operations = operations at power factor 1 multiplied by
the limitation factor. If the power factor is 0.5 at 230 Vac, 2A (750,000
operations), the limitation factor is 0.70. 750,000 x 0.70 = 525,000 total
operations.
2
24 Vac/Vdc (-5%, +10%)
DC: ca. 2 W
50 to 60 Hz
Manual START function: 40 ms
Automatic START function: 500 ms
23 Vdc (provided by control module)
40 mAdc
21 Vdc when activated
68 Ω (max.)
2 NO, 1 NC contacts
Opening of inputs (S11/S12; S21/S22): 15
ms;
Opening in supply circuit (A1(+)/A2(-)): 50 ms
Safety relay, positive-guided
1 mA to 7A (see caution)
0.1 to 250 Vac/dc
max.)
NO contact: 3 A / 230 V
NC contact: 2A / 230 V
Power factor = 1 at 230 Vac/dc (see fig. 1,
note 1)
2A
750,000 operations
5A
220,000 operations
7A
110,000 operations
Limitation Factor (see fig. 2, note 2)
0.3
0.45
0.5
0.70
0.7
0.85
1.0
1.00
1200 switching cycles/hour (max.)
Time delay 6 A (max.)
Ten million switching operations
-15°C to + 55°C (5°F to 131°F)
at 90% humidity (max.)
Housing IP 40; Terminals IP 20
Thermoplastic
Amplitude 0.35 mm; Frequency 10 to 55 Hz
2
1 x 2.5 mm
solid (max.) [14 AWG] or 2 x 1.5
2
mm
(max.) [16 AWG] stranded wire with
sleeve DIN 46288
Removable
terminal
screws; wire contacts are enclosed to prevent
electrical shock
Quick install rail mounting EN 50022-35,
width: 35 mm (1.38 in.)
220 g (0.49 lb.)
FIG 1. CONTACT LIFE FOR
100% RESISTIVE LOAD
(typical) (note 1)
power factor = 1 (cos ϕ)
]
FIG 2. LIMITATION FACTOR
FOR INDUCTIVE LOADS
(note 2)
power factor < 1 (cos ϕ)
CONTACT DAMAGE
To ensure the 1 mA capability
during the lifetime
contact, NEVER exceed 300
mA or 60 V.
strips
with
M3.5
Failure to comply with these
instructions will result in
loss
switching capability.
107035-02 EN FR26 ROW 0499 Printed in Germany