Figure 2.6 : EM inputs timing diagram
Hydraulic press
Conveyor
EM1
EM2
OSSDs
OSDs
Muting in
Muting
Muting
progress
stopped
in
progress
∆t = 40
∆t = 40 ms
(*) : EM1 and EM2 inputs are connected to sensors SM1 and SM2 for mechanical
presses.
SENSOR FAILURE
If a sensor EM fails, the next muting sequence is not allowed even if the condition of
simultaneity between sensors SMs is satisfied. In this case the muting lamp remains
permanently off (refer to chapter 4.8.3 Muting lamp output).
Restarting the module either by pressing the restart push-button in the press mode
or by using the override function in the conveyor mode., will allow the performance of a
single muting sequence ONLY.
Resetting the module by switching off and on the power supply, will allow the
performance of a single muting sequence ONLY.
Normal operation can be achieved by switching the power off, replacing the
defective EM sensor, switching the power on and restarting the module (refer to chapter
2.4.5 Manual restart of the module).
22
Mechanical press *
end muting
sensors
end muting
sensors
protective
equipment
muting
module
Muting in
Muting
Muting
progress
stopped
stopped
∆t = 40 ms