Honeywell SYA14 Series Manual page 18

Safety light curtains
Table of Contents

Advertisement

Figure 2-7 Light Curtain Resolution
Models
Resolution R
∅ 14 / 0.6
FF-SYA14
∅ 30 / 1.2
FF-SYA30
∅ 60 / 2.4
FF-SYA60
Dimensions in mm / in.
2.4.3 Protection Height
Protection height is the height from the top of the uppermost light beam to the bottom of
the lowest beam (see Figure 2-6).
2.4.4 Response Times
The response time of FF-SYA Series light curtains is the maximum time it takes the light
curtain to generate a stop signal after the sensing field has been interrupted. See the
table below for response times for individual light curtains.
Model
Response Times
number
FF-SYA14
032
14.0 ms
048
15.0 ms
064
15.5 ms
080
17.5 ms
096
19.5 ms
112
20.5 ms
128
22.5 ms
144
NA
160
NA
176
NA
NA : Not Available
18
ØR Resolution
ØR Resolution
Beam pitch P
Lens size D
10 / 0.4
4 / 0.16
20 / 0.8
10 / 0.4
40 / 1.6
10 / 0.4
FF-SYA30
FF-SYA60
13.5 ms
13.5 ms
14.0 ms
14.0 ms
14.0 ms
14.0 ms
14.5 ms
14.5 ms
15.0 ms
15.0 ms
15.0 ms
15.0 ms
15.5 ms
15.5 ms
16.0 ms
16.0 ms
17.5 ms
17.5 ms
17.5 ms
17.5 ms
107031-23 EN FR26 GLO 1199 Printed in France