FF-SPS4 Series Installation Manual

Sample Calculation

D= L/2(tan2°)+R+C
− L = 1200 in. (100 ft)
− R = 0.79 in. (SPS4)
− C = 0
− D = (1200/2) tan 2° + 0.79 in. + 0
− D = 21.75 in. (552 mm)
The minimum distance required in the United States is 100 mm (3.94 in.). Additional distance
may be required depending on the installed scanning distance.

Mounting Considerations

This section contains optical alignment and mounting information (see figures 2-3 and 2-4).
There are various ways to mount FF-SPS4 Series perimeter guarding devices (singularly, in
groups, and in different orientations). The customer is responsible for determining which
mounting method will guard the machine most effectively.