Honeywell SYA14 Series Manual page 633

Safety light curtains
Table of Contents

Advertisement

FF-SR05936 Series
FIG 3. CURRENT VS. TEMPERATURE LIMIT
-22
32
50
Ambient Temperature
Figure 3. displays the maximal recommended external
temperature versus the total load of all the safety module
contacts. To use this curve, do the following:
(1)
Follow the horizontal line from the value (vertical axis)
equal to the current inside the safety module contacts
and note intersection of the appropriate curve.
(2)
Follow the intersection point down to determine the
maximal recommended ambient temperature. (Ex: 4 A
current inside each two safety contacts, then T = 43
°
(109
F).
If the module is located in a higher temperature
environment, the lifetime of the electronic components may
be reduced. Ventilation of the cabinet may be required.
MECHANICAL INSTALLATION
The FF-SR05936 must be installed inside a NEMA 3 (IEC
IP54) rating enclosure or better.
clipped easily onto a 45mm width DIN rail (see figures 4 and
5 below for installation and removal).
FIG 4. MOUNTING DIMENSIONS
(for reference only)
a Width: 45 mm
1.77 in.
b Height: 74 mm
2.91 in.
c Depth: 121 mm 4.76 in
PK 1070-01-EN FR26 GLO 398 Printed in Germany
68
86
104 122 140 T(°F)
°
The module can be
ISSUE 1
FIG 5. INSTALLATION DIAGRAM
CONTROL RELIABILITY
"Control Reliability" means that "the device, system or
interface shall be designed, constructed and installed such
that a single component failure within the device, interface
or system shall not prevent normal stopping action from
taking place but shall prevent a successive machine cycle."
(ANSI B11.19-1990, 5.5)
OSHA 29 CFR 1910.217 states that "the control system
shall be constructed so that a failure within the system does
not prevent the normal stopping action from being applied
to the press when required, but does prevent initiation of a
successive stroke until the failure is corrected. The failure
shall be detectable by a simple test, or indicated by the
control system."
Honeywell uses self-checking techniques which combine
reliability with safety. This means that a faulty component in
our system will make the safety control modules fail in a
safe mode.
C
FIG 6. MODULE FRONT PANEL
A1
11
21
(+)
A1/A2
Zero
Motion
Continuity
Z1/Z2
12
PK 107010-01
33
43
Z1
Z2
Honeywell
FF-SR05936
A2
22
34
44
(-)
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sya30 seriesSya60 series

Table of Contents