Figure 3-12 Adjustments and Indicators
Multi-turn
potentiometer
Figure 3-13 Excess Gain Adjustment Procedure
For application help: see Warranty Information
Range selector (1 to 3)
+
Adjustment procedure
-
L = 1 mm
1. Select range number "3" with selector
1
DT1
switch DT1.
red
2. Turn the 25-turn potentiometer DT2 against
2
DT2
the arrow until the limit of travel is reached.
At the extreme position, a clicking sound will
be heard.
orange
3. Slowly turn the potentiometer DT2 in the
0
direction of the arrow until the green LED
illuminates.
DT2
3
4. If the green LED remains off and the poten-
tiometer has reached it limit of travel, select
green
DT1 range number "2" and repeat the operation.
5. If the green LED still remains off, repeat the
0
operation by selecting DT1 range number "1".
Light on
Honeywell • PK 107007-01 EN FR26 GLO 0298 Printed in France 47
Sensing threshold indicator
(visible from the panel)
Light off
Connections and Setup
Set of five LEDs used
for excess gain
adjustment (cannot
be seen with the front
panel installed).