Honeywell SYA14 Series Manual page 255

Safety light curtains
Table of Contents

Advertisement

Indication
The machine does not switch off
when an object is detected in the
safety zone
47
Possible Cause
If the red safety output LED is
illuminated, the object is detected
but the safety outputs signal are
not getting to the machine control
circuitry.
If the red safety output LED is
NOT illuminated, the object is not
detected.
No safety outputs
signals are being sent to the
machine control circuitry.
Corrective Action
Properly
seat
the
cable
between the sensor "outputs" and the
machine.
Repair
or
replace
pins/receptacles as required.
Use
a
personal
computer
FFSE.EXE
software
redefine alarm and safety zones. If the
fault cannot be rectified, return the sensor
to Honeywell (see section 8.1.2 Sales and
service).
107006-11 EN FR26 GLO 0300 Printed in Germany
connectors
cable
connector
and
the
program
to
the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sya30 seriesSya60 series

Table of Contents