Overview - Honeywell SYA14 Series Manual

Safety light curtains
Table of Contents

Advertisement

Overview

This section discusses FF- SPS4 identification, perimeter protection, specifications and
operation. This section also highlights the customer's responsibility of properly designing and
installing this perimeter guarding system.
Identification and Approval Plates
Emitter and receiver have two plates, an identification plate and an approval plate (see figures
1-1 and 1-2).
The identification plate contains the following:
• Scanning range (m)
• Catalog listing (Type)
• Power supply voltage (V)
• Power consumption (P)
• Power supply frequency (F)
• Max. switching capacity of output relays
• Serial number and date code (month and year)
• Response time
• Sealing
The approval plate certifies that the product conforms to the technical examination
endorsement issued by the approval institutes of different countries.
Figure 1-1 Identification Plate
FF-SPS4
SPE
SPE
øR
L
Scanning range
øR
L
SPE
Type
V
P
F
I
/V
max
max
T
NEMA/IP
For application help: call 1-800-537-6945
'HVFULSWLRQ DQG
Type
L
SPR
V
P
F
I
/V
max
max
Resolution
SPR
Scanning range (m)
Product listing
Power supply voltage
Power consumption
Power supply frequency
max. switching capacity of output relays
Serial number and date code
(month and year)
Response time (ms)
Sealing
2SHUDWLRQ
N °
(F) 38240 MEYLAN
T
SERVICE :
response time
GB: 0161/251 4079
F: 01 60 19 80 41
NEMA
D: 069/8064-444
USA: 1/8005376945
IP
Honeywell • MICRO SWITCH Sensing and Control 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sya30 seriesSya60 series

Table of Contents