40FY Series
Step 3 - Test the 40FY sensor as
follows:
• Actuate the door interrupt sensor
and ensure the target indicator
LED indicates as follows:
Magnetic
Actuator
Present
Normally
LED OFF
Closed
Normally
LED ON
Open
• If the door interrupt sensor fails to
operate correctly, ensure wiring
and alignment are correct.
• If the sensor still does not work,
return the product to Honeywell.
For application help: call 1-800-537-6945
SPECIFICATIONS
Sensor Type
Sensing Distance
Min. Operate
Max. Release
Magnetic
Actuator
Absent
Supply Voltage
LED ON
Load Current
Leakage Current
LED OFF
Voltage Drop, max.
Current
Consumption,
max.
Inrush Current,
max.
Repeatability*
Operating
Temperature
Protection Class
Materials
Circuit Protection
* Repeatability is the ability of the sensor to trigger at the same point, plus
or minus a given tolerance, after every operation (at constant voltage and
temperature) over the entire range of the sensor's specifications.
** Application Note: Enclosures are based, in general, on the broad
definitions outlined in NEMA standards. Therefore, it will be necessary for
the user to determine that a particular enclosure is adequate when exposed
to the specific conditions that might exist in intended applications. Except
as might otherwise be noted, all references to products relative to NEMA
enclosure types are based on MICRO SWITCH evaluation only.
ELECTROMAGNETIC COMPATIBILITY
Characteristics
Impulse Voltage Withstand
Radiated Electromagnetic Field
Immunity
Electrostatic Discharge (ESD)
Immunity
Fast Transient Immunity
Radiated Emissions
Conducted Emissions as Required
3-wire DC
41FY1
41FY2
6,35 mm
7,6 mm
(.25 in.)
(.30 in.)
15,24 mm
19,05
(.60 in.)
mm
(.75 in.)
10 to 30 VDC
0 to 200 mA
30 mA
PNP: 2.5 V
NPN: 1.5 V
40 mA
± 3%
-30 to +85°C
(-22 to +185°F)
IP 67 (Dust tight, temporary immersion)
NEMA** 4, 6, 6P, 13
Housing: Polycarbonate. Cable: 22 gage PVC
Transients (power and output), incorrect wiring
Standard
IEC255-5
IEC801-3
IEC1000-4-2
IEC1000-4-4
CISPR 11
CISPR 11
Honeywell • MICRO SWITCH Sensing and Control 3
PK 80370
1557-
2-wire AC
41FY1
41FY2
7,6 mm
10,2 mm
(.30 in.)
(.40 in.)
19,05 mm
25,4 mm
(.75 in.)
(1.0 in.)
93 to 132 VAC
0 to 500 mA
1.5 mA max.
6 V @ 500 mA
1.2 A/20 msec
± 3%
-25 to +70°C
(-13 to +158°F)
Level
1 KV
3 V/m
8 KV
1 KV
within
specified
limits
within
specified
limits