Installation Instructions for the
MICRO SWITCH Maintained Cable Pull
Limit Switch
GENERAL INFORMATION
The Maintained Cable Pull Limit Switch is
l
designed for use in emergency stop applications.
Single or duplex head Cable Pull Limit Switches
l
are designed to forcibly disconnect a set of direct
acting switch contacts.
Direct acting switch contacts are held closed
l
when actuating cable(s) are under proper
tension. When cable is pulled, slackened or
broken, a cam positively opens the switch
contacts.
Switch contacts remain open until switch is reset
l
by manually depressing the reset button located
on the actuated operating head.
When direct acting switch contacts open,
l
auxiliary contacts also actuate: open contacts
close and closed contacts open.
SINGLE HEAD VERSION (Figure 1)
Direct acting switch contact: 1 NC (normally
l
closed).
Auxiliary contact: 1 NO (normally open).
l
Head may be positioned in any of four directions.
l
Figure 1: Single Head Version
MICRO SWITCH Sensing and Control
DUPLEX HEAD VERSION (Figure 2)
Primary basic switch (left side of switch):
l
- Direct acting switch contact: 1 NC.
- Auxiliary contact: 1 NO.
Auxiliary Basic Switch (right side of switch):
l
- Four options available.
Heads may be positioned in any of three
l
directions, allowing actuating cables to run in
opposite directions or at right angles to one
another.
Figure 2: Duplex Head Version
AUXILIARY CONTACTS
Additional contacts are electrically isolated from
l
the direct acting switch contacts. Used for
monitoring or signaling, i.e., indicators, pilot lights
and alarms.
MAXIMUM ACTUATING CABLE LENGTH
Depending upon variations in ambient
l
temperature, maximum cable length in a single
direction is 200 ft. (60 m) for a total of 400 ft.
(120 m).
TENSION INDICATOR
Convenient tension indicator line on switch
l
plunger indicates maximum preset cable tension.
OTHER AVAILABLE FEATURES
Conduit openings and indicator/pilot light options.
l
Hardware kits and cables for various length
l
installations.
Honeywell
lSSUE 3
PK 8156 0