4. Electrical Connections
4.1 Overview
This chapter contains information about electrical installation and wiring
IMPROPER INSTALLATION
Strictly adhere to all electrical connection instructions.
Failure to comply with these instructions could result in death or serious injury.
4.2 Wiring diagram
Figure 4.1 : FF-SRM module inputs and outputs
Power supply source for the
module and inputs (chapter 4.2.)
Mode selection (chapter 4.3.)
Muting lamp output (chapter 4.7.3.)
Restart and OSDs
status outputs
(chapter 4.7.4.)
output connected to the FSD (chapter 4.6.1.)
Input for start muting sensor
(chapter 4.5.1.)
Input for end muting sensor
(chapter 4.5.2.)
Input for protective equipment
(chapter 4.4.1.)
Input for override push-button
(chapter 4.7.1.)
107004-15 EN FR26 ROW 0899 Printed in France
Power supply source for outputs (chapter 4.2)
SSD monitoring loop (chapter 4.6.3.)
SSD output (chapter 4.6.3.)
Test ouput for the protective
equipment (chapter 4.4.2.)
Restart input (chapter
4.7.2.) & FSDs monitoring
loop (chapter 4.6.2.)
output connected to the FSD (chapter 4.6.1.)
Input for start muting
sensor (chapter 4.5.1.)
Input for end muting
sensor (chapter 4.5.2.)
Input for protective
equipment (chapter 4.4.1.)
Input for override push-button
(chapter 4.7.1.)