Honeywell SYA14 Series Manual page 471

Safety light curtains
Table of Contents

Advertisement

50FY Series
Step 3 - Wire sensors to logic amplifier as
follows:
• Old component versions (amplifier, FYQLA-140R-
1 and sensor, 50FY40) cannot be ordered.
However, for maintenance purposes, the new
components (amplifier, FYQLA-140R-3 and
sensor, 50FY41) may be used in an old
installation (see installation warning).
• The 52FY30 magnet actuators will work with
50FY41 sensors, however, the sensing distance
will increase.
a. 50FY41 sensor (new) with FYQLA1-140R-3
amplifier (new)
• Connect each sensor (see Wiring Diagram) via its
four leads as a set to the logic amplifier as
follows:
FYQLA1-140R-3 (new)
R (positive)
W (normally open)
B (negative)
O (normally closed)
• To secure power and sensor leads, torque
connector screws 0,56 Nm (5.0 in.-lb.).
WIRING DIAGRAM
• If less than six sensors are connected to the logic
amplifier, install two 22 K Ω resistors across each
unused logic amplifier terminal set as follows:
Logic Amplifier Terminals
R - W
B - O
*The resistors are necessary for the proper operation
of the logic amplifier. Ten 22 K Ω resistors are
supplied with each 50FY Series system.
50FY41 (new)
RED - positive
WHITE - output
BLACK - ground
ORANGE - output
Resistor*
22 K Ω resistor
22 K Ω resistor
Honeywell • MICRO SWITCH Sensing and Control 3
IMPROPER INSTALLATION
• This product is designed to conform to the
technical requirements of EN954 Category III and
ANSI B11.19-1990. To ensure compliance with
these requirements, 50FY41 sensors MUST be
used with the FYQLA1-140R-3 logic amplifier.
• Strictly adhere to all installation instructions.
Failure to comply with these instructions could
result in death or serious injury.
b. 50FY41 sensor (new) with FYQLA1-140R-1
amplifier (old)
• Cut and remove the ORANGE sensor leadwire.
• Connect the RED, WHITE and BLACK sensor
leadwires to the logic amplifier terminals as
follows:
FYQLA1-140R-1 (old)
R (positive)
W (normally open)
B (negative)
• To secure power and sensor leads, torque
connector screws 0,56 Nm (5.0 in.-lb.).
c. 50FY40 sensor (old) with FYQLA1-140R-3
amplifier (new)
• Connect the RED, WHITE and BLACK sensor
leadwires to the logic amplifier as follows:
FYQLA1-140R-3 (new)
R (positive)
W (normally open)
B (negative)
O (normally closed)
• Install one 22 KΩ resistor between the BLACK
and ORANGE logic amplifier terminals.
• To secure power and sensor leads, torque
connector screws 0,56 Nm (5.0 in.-lb.).
Special instructions related to 50FY40 sensors
used with FYQLA1-140R-3 amplifier
If the door is open more than one second and
power to the amplifier is ON, the ATTENTION
INDICATOR LED will flash. To return to a green
condition, close the door(s), shut amplifier power
OFF and wait until the ATTENTION INDICATOR
LED is completely OFF, then turn the amplifier
power ON (power on reset).
PK 80391
ISSUE 3
50FY41 (new)
RED - positive
WHITE - output
BLACK - ground
ORANGE REMOVED
50FY40 (old)
RED - positive
WHITE - output
BLACK - ground
NO ORANGE LEAD