Honeywell SYA14 Series Manual page 64

Safety light curtains
Table of Contents

Advertisement

5.3 Troubleshooting Procedures
When the FF-SYA Series safety light curtains are working properly and the sensing field is not
interrupted, at least one of the emitter yellow LEDs R1, R2 and R3 is illuminated, the receiver
green LED «ON» is illuminated, and all other LEDs are NOT illuminated. If this condition is not
met, refer to the following troubleshooting chart, flow diagram and corresponding repair
procedures.
Troubleshooting Chart (see next figure for indicator information)
Symptom
Probable Cause
All light emitting diode
No power.
(LED) indicators are NOT
illuminated
The emitter red « test »
Test input is open.
indicator and the receiver
red « OFF » operation
indicator are both
illuminated
The emitter red « alarm »
Emitter is having a
indicator is flickering and
failure
the receiver red « OFF »
operation indicator is
illuminated
The receiver red cross-talk
Receiver is
indicator is « ON » and the
receiving a signal
receiver red « OFF »
from a second
operation indicator is
emitter
illuminated
The receiver yellow signal
Emitter and/or
strength indicator is
receiver units need
flickering and the green
to be cleaned
« ON » operation indicator
Emitter and/or
is illuminated
receiver units need
to be aligned
Emission power is
too low
The receiver yellow signal
Emitter and/or
strength indicator is
receiver units need
flickering and the red
to be cleaned
« OFF » operation
Emitter and/or
indicator is illuminated
receiver units need
to be aligned
Emission power is
too low
64
Corrective Action
Ensure external fuse is not blown.
Ensure supply voltage and polarity
are correct (see Specifications).
Ensure electrical power connections
are secure and correct. (see
Electrical Connections chapter).
Ensure the external circuit wiring
connection between pins 4 and 5 on
the emitter connector is secure (see
Electrical Connections chapter,
Mutual Interference or Cross-talk).
Replace the emitter unit by a new
one of the same resolution and
protection height
Adjust the emission power of the
second emitter (see chapter
Installation)
Clean emitter lens, receiver lens
and mirrors (see Emitter and
Receiver Cleaning).
Align emitter, receiver and mirrors
Adjust the emission power of the
emitter (see Installation chapter,
Mutual Interference or Cross-talk)
Clean emitter lens, receiver lens
and mirrors (see Emitter and
Receiver Cleaning).
Align emitter, receiver and mirrors
Adjust the emission power of the
emitter (see Installation chapter,
Mutual Interference or Cross-talk)
107031-23 EN FR26 GLO 1199 Printed in France