Figure 4-5 Receiver receptacle pinout (Minichange plugs color code)
(DC+)
Connector Pinout
1A Fuse
1.5A max Fuse
FF-SYAqqqqqC2
1
3
2
internal
FF-SYA
fuse
receiver
3
2
6
4
5
K3
K1
K3
K2
(1)
Hirschmann N6RFF
(1)
Receiver plug
(Crimped contacts inserted
K1
K2
FSD
FSD
this side)
(DC-)
1 : (DC+) main power supply
2 : (DC-) main power supply
3 : (DC+) outputs power supply
6 : (DC-) outputs power supply
4 : output (loads connection)
5 : output (loads connection)
: earth
107031-23 EN FR26 GLO 1199 Printed in France
FF-SYAqqqqqQ2
1
6
4
5
7-pole receiver receptacle
(compatible with Brad Harrison
Mini-Change plugs)
1 (WHITE/BLACK) : (DC+) power supply
2 (BLACK)
: (DC-) power supply
3 (WHITE)
: (DC+) outputs power supply
4 (RED)
: outputs (load connection)
5 (ORANGE)
: outputs (load connection)
6 (BLUE)
: (DC-) outputs power supply
7 (GREEN)
: earth